Drill depth issues
-
- Posts: 2
- Joined: Thu Dec 31, 2020 3:11 pm
Drill depth issues
In the drilling operation, if there is a value entered for approach distance, this value is added to the drill depth when posted, therefore I always change this value to zero. Is there a way to always ensure this value is zero as if I miss changing this then the holes are drilled 2.5mm deeper than they should be. Alternatively can I edit the post script to ignore the drill depth value?
PtM
-
- Posts: 2405
- Joined: Wed Aug 01, 2007 4:15 pm
- Location: Irvine, CA, USA
- Contact:
Re: Drill depth issues
You can use save as defaults to save the mop parameters to a defaults file. Right click on the operation and select save a defaults.
Please let us know the post processor you are using so we can verify the drill depth variable that is used. On most posts Z[CYCL_Z-DEPTH] variable outputs only the specified depth without adding the approach distance.
Please let us know the post processor you are using so we can verify the drill depth variable that is used. On most posts Z[CYCL_Z-DEPTH] variable outputs only the specified depth without adding the approach distance.